OSSO

← Nov 01 Nov 09 →

Journal: Monday, Nov 02, 2026

  1. 2026-11-02: run 26, flex trays, PP and lube inside, tube vials, ghost box
  2. 2026-11-02: run 27, tray R full reach, N7 hot-air needle, removable outer panel + inner e-plate 0-90

2026-11-02: run 26, flex trays, PP and lube inside, tube vials, ghost box

Nov 02, 2026 · #

Built on run 25 (snapshot v25). One flexible SMT/TH tray system as big as possible on each side of the PCB pocket (still on the galvo axis): tray L 102x162 (4x6, 23 usable cells), tray R 269x162 (11x6, 62 usable); QR tag 12x12 in the front-left cell; ESD lids resized (clear anti-static acrylic, 25 mm, frosted finger tab). Reach, any needle: tray L 96.1 %, tray R 86.2 % (X 690-727 out of reach); PCB 100 %. PP unit inside on the front floor with a front louvre and duct; lube (OPTIONAL) inside the E-zone column. Flush tube vials front (L-R) and both sides (F-B). Ghost box below the laser: 335x150x170 mm (8.54 L), in the STEP. Panel fasteners in the panels subassembly. Static 93 hits, 0 non-fastener; sweeps 0 clashes; tip-over SF 2.65 (conservative 1.92). SR-034..036 added. Notes: project/docs/run26_design_notes.md.

2026-11-02: run 27, tray R full reach, N7 hot-air needle, removable outer panel + inner e-plate 0-90

Nov 02, 2026 · #