# Laser technical summary: 10W 355nm UV galvo marker

Used for OSSO: polyimide stencil cutting and PCB blank ablation. Owned lenses: 150 mm field (preferred) and 300 mm field.
All values are taken from the two vendor documents (originals in `project/refs/laser/source_private/`, not published). "Not stated" means neither document gives the value.

| Item | Value (as stated) |
|---|---|
| Machine | 10W water-cooling UV laser marking machine |
| Laser source | CRS UV laser source 10W, model CRS-355-10 |
| Wavelength | 355 nm (central emission) |
| Average output power | 10 W nominal; power adjustment 10%–100% |
| Power stability | < ±3% (average power) |
| Pulse width | < 15 ns at 40 kHz |
| Pulse repetition rate | 20 kHz – 150 kHz |
| Pulse stability | RMS ≤ 3% at 40 kHz |
| Beam roundness | > 90% |
| Beam quality (M²) | Not stated |
| Spot diameter | 0.4–0.7 mm (see note 2) |
| Galvo head | RC1001 Sino-Galvo |
| Marking speed | 0 – 7000 mm/s |
| Lens / marking field | F-theta 150 × 150 mm (supplied); 300 × 300 mm quartz field lens (supplied); 50 × 50 to 300 × 300 mm available (see note 1) |
| Focal lengths | Not stated |
| Working distance | Not stated |
| Z travel | Not stated |
| Table / bed | Not stated |
| Repeatability | Not stated |
| Marking depth / line width | Not stated |
| Rotary | Not stated (not listed as included) |
| Cooling | Water cooling |
| Laser power supply | Taiwan Meanwell |
| Operating voltage | 110 V / 50 Hz; supplied as 110 V with US plug (see note 3) |
| Average consumption | 350 W |
| Working temperature | 0–40 °C |
| Storage temperature | −15 °C to 50 °C |
| Dimensions / weight | Not stated |
| Control | JCZ EzCad marking control card and software; compatible with LightBurn |
| OS support | WinXP / Win7 / Win10, 32-bit and 64-bit; English operating system |
| Image formats | "Amp" (as printed), JPG, GIF, TGA, PNG, TIF, etc. |
| Vector formats | AI, PLT, DXF, DST, etc. |
| Interfaces | Not stated (USB drive supplied for software/settings backup) |
| Certificates | CE, FDA, RoHS (printed "CEFDA ROHS") |
| Included accessories (tech) | Foot switch for marking; one pair of protective glasses; USB drive with software and settings backup; training project/export/video and instruction book |

## Notes and conflicts
1. Marking field: both documents list a 150 × 150 mm F-theta lens; the spec sheet also lists the 300 × 300 mm quartz lens and gives a range "50 × 50 to 300 × 300 mm for choice". Neither gives focal length or working distance for any lens, so the 150 mm field lens's focal distance must be measured on the machine.
2. Spot diameter "0.4–0.7 mm" is far larger than a typical focused UV galvo spot. It may refer to the raw beam rather than the focused spot. Treat it as unverified, and measure the kerf on the practice film.
3. Operating voltage is printed as 110 V/50 Hz, while the supply is described as 110 V with a US plug (US mains is 60 Hz). This is probably a typo; check the PSU label.
4. "Detail training project/export/video, instruction book" appears twice in the included list (items 9 and 12). This is a duplicate, not a conflict.
5. "Amp" in the image formats is printed as-is (probably BMP).