| ID | Rule | Source | Added |
|---|---|---|---|
| SR-001 | XYZ collision avoidance is done in software as a motion-planner rule table (keep-out zones per tool/head position). | Standing design rule | 2026-11-01 (recorded) |
| SR-002 | Head v5: needle-down minimum T 492 for head X 330-490 below Z 380 (clears the up-camera needle sensor board); T 462 elsewhere. | Head v5 rule, 2026-10-31 | 2026-11-01 (recorded) |
| SR-003 | Laser hood (run 32, fixed hood): the hood is fixed to the laser column at the height set on the two manual jack-screw adjusters; there is no hood motion and no hood command. The laser fires only when (a) the coded dual-channel hood-sealed sensor is made (hood mounted at its commissioned height, tab on the fixed hood), AND (b) the tray is at the laser station (Yc 442 +/- 0.2) so the PCB pocket is under the hood with the v1e silicone band (1.5 mm, 50-60A, tip 0.5 mm into the work plane) wiping on the board and frame. The sensor is wired in series in the hardware laser enable chain and is also read by software. | Laser hood v1f, 2026-11-01; run 32 fixed hood 2026-11-03 | 2026-11-03 (run 32) |
| SR-004 | Door interlock (hardware): the two coded dual-channel door sensors, in series in the laser enable, cut the laser when the door lifts 5 mm or more. Software must also read both sensors and treat either as door open. | Gull-wing door option, 2026-11-01 | 2026-11-01 |
| SR-005 | Door-open alert: when the door is open, show a "Door open" warning on the touchscreen at once; if it stays open past a set time (default 60 s, configurable), sound a chime and repeat. | the designer, 2026-11-01 | 2026-11-01 |
| SR-006 | Door open = enclosure positive pressure lost: flag "enclosure not protected" while the door is open and log the exposure time for paste and parts; clear it once the door closes and pressure recovers. | the designer, 2026-11-01 | 2026-11-01 |
| SR-007 | Enclosure positive pressure (optional, can be left out): run the filtered inlet fan whenever a job is active. Closed-loop PWM on the bay differential pressure sensor to hold 3.5 Pa (band 2-5 Pa). With the door closed (SR-004 sensors), if dP < 1.5 Pa for more than 60 s at PWM >= 90 %, or the fan tach reads < 50 % of the commanded speed, show "Inlet filter clogged / check leaks" (non-blocking warning, job continues). Suppress the check while the door is open and for 120 s after it closes (pressure recovery, see SR-006). | Positive-pressure option, 2026-11-01 | 2026-11-01 |
| SR-008 | Status light bar (applies ONLY if the optional light bar is fitted; the touchscreen is the primary status indicator): show the highest-priority active state, each with a distinct colour AND pattern (never red vs green): P1 error = orange fast blink 4 Hz; P2 laser firing = white solid 100 %; P3 laser armed = white double flash every 1.5 s; P4 door open = yellow wig-wag (halves alternate 1 Hz); P5 needs attention = orange slow breathe 0.5 Hz; P6 positive pressure lost (only if that option is fitted) = sky-blue end pixels blink 0.5 Hz as an overlay on the lower state; P7 paused/hold = yellow solid 60 %; P8 job done = blue triple flash every 5 s, until the door opens or 10 min; P9 running = blue single-pixel chase L to R 1 s per pass over dim blue; P10 idle = sky blue solid 10 %. Bar off if the controller is not booted; brightness user-set (default 60 %). | Status light bar option, 2026-11-01 | 2026-11-01 |
| SR-009 | Swing-out electronics plate (applies only if that option is fitted): the e-plate door interlock (coded, dual channel, in the safety relay chain) is the hardware path; software mirrors it. Door open = no motion, laser disabled, heaters (SSRs) off, a job cannot start; if it opens during a job: controlled stop then the E-stop path, show "Electronics door open" and log it. 24 V stays on for diagnostics. Resume only after the door is closed and the operator confirms. | Swing-out e-plate option, 2026-11-01 | 2026-11-01 |
| SR-010 | Level check (the built-in vials are the primary level check; the accelerometer is on the custom electronics PCB, which is mounted on the swing-out e-plate): at boot and before a job, with motion stopped and the e-plate door closed (SR-011), average the PCB accelerometer for 1 s. If X or Y tilt > 2 mm/m, show "Machine not level - check the vials" (non-blocking warning). Store the reading taken after leveling, door closed, as the zero and flag a change > 1 mm/m (foot moved, bench sagged or plate not seated). | Leveling feet option, 2026-11-01; accelerometer moved to the electronics PCB in run 20 | 2026-11-01 (rev run 20) |
| SR-011 | Level reading validity: because the accelerometer swings with the e-plate, a tilt reading is valid only while the e-plate door interlock (SR-009) reports closed and has been closed for at least 2 s. Discard readings taken while it is open; never store a zero with the door open. | Run 20, 2026-11-01 | 2026-11-01 |
| SR-012 | Gull-wing door open state is held by the two 80 N gas struts only: no motion that could reach above the door sill (Z 150) while the door is moving (door sensors changing state), and the light bar / touchscreen show "Door open" per SR-005 until both sensors read closed. | Run 20, 2026-11-01 | 2026-11-01 |
| SR-013 | Laser hood working distance is a configuration parameter (nominal 240 mm, lens bottom to film). The firmware reads it from the machine config and refuses to arm the laser if the configured value differs from the hood build value recorded at commissioning. SR-003 still applies. | Run 20, 2026-11-01 | 2026-11-01 |
| SR-014 | Rotation-plate index (run 21, no rotation motor): the plate turns only when the tray drives the pinion onto the fixed rack (m0.5, pinion Z32, 7.16 deg per mm of tray travel, engagement only at T < 386.5). Index move: from T >= 392 drive the tray down to T = 386.5 - (angle / 7.16) (min T 360; the fixed laser hood v1f limits the tray to T >= ~357), then back to T >= 392; the one-way clutch makes the return stroke free, the 32-position detent (11.25 deg) holds the plate. After every index read the AS5600 encoder: error > 1.5 deg = re-index (one retry), then "Rotation index fault" and pause. Angles over 190 deg take two strokes. | Run 21, 2026-11-01 | 2026-11-01 |
| SR-015 | Index zone keep-out: while T < 392 (index zone) the head must be parked at Z >= the HOME height and outside X 330-500, no paste/pick/laser action is allowed, and the tray speed in the zone is limited to 20 mm/s (rack entry) with the plate encoder read at zone exit. Normal work positions are T >= 392 (rack teeth never touched); T < 360 is never commanded (soft limit, hood). | Run 21, 2026-11-01 | 2026-11-01 |
| SR-016 | Interior LED lighting (24 V, 4000 K, diffused, shaded by glare fins): on when either door interlock (gull-wing SR-004 or e-plate SR-009) reports open, and off 10 s after both read closed. During camera capture (fiducial / up-camera / inspection) the interior LEDs are forced OFF (the cameras use their own ring lights); a user "light on" toggle on the touchscreen overrides, except during capture. | Run 21, 2026-11-01 | 2026-11-01 |
| SR-017 | Central lube reminder (manual one-shot pump, PDI metering, one fill point on the right side outside the panels): count axis travel per axis; when any axis passes 50 km or 100 operating hours (whichever first, configurable), show "Lubricate: 1 stroke of the lube pump" on the touchscreen at the next idle. The operator confirms the stroke; then the controller runs a distribution cycle (each axis full travel x3 at 50 % speed, tray stays at T >= 392 per SR-015) and resets the counter. Low level is a visual sight window check (no sensor). | Run 21, 2026-11-01 | 2026-11-01 |
| SR-018 | PCB load / unload pose: before the door-open prompt, move the bed to Y 420 (front), head to X 650 and Z HOME, tray to T 540; laser disarmed (SR-003). The hand-access check (run 21) is valid only in this pose. | Run 21, 2026-11-01 | 2026-11-01 |
| SR-019 | (SUPERSEDED by SR-039, run 27) E-plate 0-180 deg: the plate has detents at 90 and 180 deg and a mechanical stop at 185 deg. SR-009 applies at every open angle. No rule on the gull-wing door state is needed for tip-over (SF >= 1.5 in all cases, run 21 check), but the touchscreen shows "Close the electronics plate before moving the machine" whenever it is open. | Run 21, 2026-11-01 | 2026-11-01 |
| SR-020 | Cool-air intake vs positive pressure (PP) mode: the config holds pp_mode (installed / not). Without PP the e-plate door intake (G4 filter) is open and the cabinet fans pull fresh air past the PSUs/drivers into the bay. With PP fitted the magnetic intake blank must be fitted (the PP plenum then feeds the E-zone); a reed switch on the blank is read and a mismatch (pp_mode on and blank missing, or off and blank fitted) shows a non-blocking warning. Intake filter reminder every 500 h. | Run 21, 2026-11-01 | 2026-11-01 |
| SR-021 | Hood set-up and interlock (run 32, replaces the run 22 hood-drop rule; drop cylinders, valve channel and hoses removed): the hood never moves in operation. Set-up order: (1) set the laser focus (galvo/lens height, focus test); (2) set the hood height once on the two slotted jack-screw adjusters (+/-6 mm, scale) so the silicone band tip is 0.5 mm into the work plane (PCB top) on all four sides; (3) commissioning: the software checks that the hood-sealed sensor is made and records it; the tray runs a slow pass Yc 105 -> 442 -> 105 under the band (band wipes the chamfered pocket frame and board; tray motor current must stay within the taught band, else "Hood band snag - check the hood height"). After any focus change the software blocks the laser ("Hood height not confirmed after focus change") until steps 2-3 pass. In operation: if the hood-sealed sensor opens at any time, the laser enable chain drops in hardware and the job stops with "Hood not in place". Tray moves under the hood are limited to 60 mm/s while the pocket frame is under the band (X 229-397). | Run 22, 2026-11-02; rewritten run 32, 2026-11-03 | 2026-11-03 (run 32) |
| SR-022 | RETIRED in run 32 (fixed hood, no cylinders or reed switches). Kept behavior: if the hood-sealed sensor opens while the laser is armed or firing, the laser is cut at once (hardware), the job pauses with "Hood not in place", and the fume fan keeps running for 30 s. Tray motion is no longer gated by a hood position (see SR-021 for the speed limit under the band). | Run 22, 2026-11-02; retired run 32 | 2026-11-03 (run 32) |
| SR-023 | Tray load and index zone: the load position is Yc 105 at the front, behind the gull-wing door. The tray moves to the load position only with the head parked (no motion while the door is open, SR-004 unchanged); the operator loads with the door open, START after the door closes. Travel is Yc 105..515 (410 mm). The rotation plate indexes only inside Yc 470..502 (pinion on the fixed rack, one-way clutch): the planner must not stop the tray inside 461..505 except for an index stroke, and the laser station Yc 442 is outside the zone (rack first contact at Yc 461.5). | Run 22, 2026-11-02 | 2026-11-02 |
| SR-024 | Front HMI pod and laser service (run 22): the touchscreen, key switch, emission lamp, START and HOLD are on the front pod with the e-stop directly under them (e-stop hard-wired, SR-004/SR-009 unchanged; the software reads its auxiliary contact and shows "E-stop pressed"). Laser service is by removing the whole rear panel (no service door): the rear panel is tool-removed and carries a coded interlock in the laser enable chain; with it open the laser cannot arm and the screen shows "Rear panel open - laser locked out". The fume duct is fixed through the rear panel and is unplugged with it. Revised run 30: the rear panel carries the rear service panel with every external connection (SR-049); before the rear panel comes off, the screen lists them: "Disconnect AC, coolant, Ethernet, chiller alarm, fume fan and exhaust first". | Run 22, 2026-11-02 | 2026-11-02 |
| SR-025 | Head X soft limits, PCB datum and reach (run 23, revised run 24, rewritten run 35): head X travel 193..640 (soft limits 195 / 638; the left limit is set by the 200 mm slide body vs the left inner wall and the X carriage bridge, so the X-min sensor stays). ONE 140x140 PCB per job in a 145x145 pocket, now at the rear (tray frame Y 84..224; its rear edge is the needle tip line). Loading: push the board into the front-left corner stop and along the front lead-in rail (the run 35 loading datum, both 0.6 mm tall so the hood band wipes over them), then onto the fixed -X / -Y pads; flexures on +X / +Y. The PCB is valid only when seated (pocket check + the 2 fiducial discs in front of the PCB before any dispense or laser). Laser: the galvo job is offset by the calibrated (dx, dy) of PCB centre vs galvo axis at Yc 411 (was 442; config laser_offset_xy, laser blocked until calibrated). The planner checks every needle against the limits per job: N1, N2, N4, N5, N6, N7 and N8 reach 100 % of the PCB; N3 (IPA, slot 8) reaches 87.1 % (PCB X >= 263) and is a cleaning needle, so IPA spots left of that are rejected at import ("IPA spot out of reach"); every pick is checked against the tray reach map (N4, N5, N8: 100 %). Reach is checked inside the soft limits, not the hard travel: PCB at machine X 245-385 (+2 mm for N5 at X 195), tray pockets over X 451-648 (N4 at X 638); the tray's right frame wall X 648-650 is not reached and holds no pocket. | Run 23, 2026-11-02 | 2026-11-04 (run 35) |
| SR-026 | E-plate door electronics (run 23): PSUs and drivers ride on the door; door intakes (2 louvred G4 filters) feed the PSUs and drivers first. SR-009 door interlock and SR-019 detents unchanged; with the door open past 5 deg the motor drivers are disabled (no motion) while logic stays powered for diagnostics. Filter reminder every 500 h covers both door filters. | Run 23, 2026-11-02 | 2026-11-02 |
| SR-027 | Calibration plate CAL-01 (run 25): the calibration plate is stored OFF the machine in a padded case (no e-plate door sleeve). The up-camera scale tile stays on the machine; N4 picks it for the up-camera scale check. The calibration wizard asks for the plate, checks its ID mark with the angled crosshair camera, and refuses to save results if the plate ID or the scale-tile check fails. | CAL-01 option drawing, run 25 | 2026-11-02 |
| SR-028 | Fire watch FW-01 (run 25): T1 NTC (exhaust temperature) and F1 IR flame sensor on the fixed duct feed a latching relay K1 in the laser-enable chain (series with the existing force-guided enable relay). A trip latches laser enable OFF in hardware; software shows the cause and needs an operator reset after inspection. On every trip the extractor stays ON (no damper) and the hood stays DOWN. S1 smoke sensor is optional (bay and connector reserved; ignored when absent). Self-test of T1/F1 at power-up; a failed self-test blocks laser jobs. | FW-01 option drawing, run 25 | 2026-11-02 |
| SR-029 | Job QR JQR-01 (run 25): every job PCB carries a job QR patch on BOTH sides, mirrored, at the near edge (board X 66-74, Y 9-17; PCB_RULES PR-QR). The angled crosshair camera reads it before any operation and after each flip; the job is blocked if the code does not match the loaded job and side. After 3 failed reads the operator may type the ID; the override is allowed and logged with the job. | JQR-01 option drawing, run 25 | 2026-11-02 |
| SR-030 | Tray lids EL-01 (run 25): clear anti-static acrylic lids, 12 mm max part height, lid top 25 mm above the insert. Lid presence is detected by the camera only (engraved frosted mark on each finger tab; no magnets or hall switches). Any lid seen on a tray blocks head motion over that tray. Lids are stored off the machine. | EL-01 option drawing, run 25 | 2026-11-02 |
| SR-031 | Not used. The TS-01 tray scale and pointers were removed in run 31 (no hardware, no software rule). | the designer, run 31 | 2026-11-03 |
| SR-032 | Part tray QR (run 25): each part tray insert (TH and SMT) carries a QR tag in its front-left cell, positioned from the shared -X/-Y datum. The crosshair camera reads both tags at job start (and after any door opening); the code gives tray type and ID and its position confirms the insert is seated. The job is BLOCKED on any tray QR mismatch (wrong tray, wrong type, missing, or out of position). | Run 25 design | 2026-11-02 |
| SR-033 | No custom stencils or per-job masks, ever: paste, masking and isolation come only from the fixed tools and the laser; a job that needs a custom stencil or mask is rejected at import. | the designer, run 25 | 2026-11-02 |
| SR-034 | Flexible tray layout from the QR (run 26): tray L and tray R are one tray system. Each QR gives the tray ID, the type (SMT, TH or MIXED), the grid (columns x rows, pitch) and the cell-map revision. The planner builds the pick map from the QR, not from the slot. SR-032 still applies: a QR mismatch (wrong tray, type, grid or revision, missing, or out of position) blocks the job. | Run 26 design | 2026-11-02 |
| SR-035 | Reach-aware cell assignment (run 26): at job import, each part is assigned only to a cell its tool can reach (needle N1-N6 by size, hot air X 193-640 machine). Tray L is never reached by N6, and its cells left of X 143 by no needle. Any part in an unreachable cell blocks the job, with the cell and tool named. | Run 26 reach check | 2026-11-02 |
| SR-036 | Optional lubrication (run 26): the lube pump is a config option. If it is fitted, the run-hour reminder prompts a one-shot stroke. If it is not fitted, the reminder prompts manual greasing of the listed points. Neither blocks a job. | Run 26 design | 2026-11-02 |

| SR-037 | Hot-air station N7-HA (run 27, in the needle set left of N1, replaces the front hot-air bracket): focused jet only, no masks (SR-033). Standoff 1.5 +/- 0.3 mm (tip Z taught with the needle touch-off, re-checked each job), air <= 350 C, flow 1.2-1.8 L/min, dwell <= 8 s per joint, jet perpendicular to the board. The planner blocks a hot-air joint whose center is < 2.0 mm from a neighbor joint not being reflowed or < 3.0 mm from TH plastic (body/housing outline from the footprint), naming the part. Heater on only while N7 is lowered or within 30 s of use; the slider temperature (N7 bushing NTC) > 90 C = heater off and "N7 overheating". | Run 27 design (hot_air_calc.json) | 2026-11-02 |
| SR-038 | Tray R full reach (run 27): tray R is X 458-686 machine, 9x6 cells (pitch 25.1 x 26.7), QR in the front-left cell, 52 usable cells, every cell reachable by N1-N6 and N7-HA does not pick. SR-035 is revised: tray R never blocks a job for reach; tray L rules unchanged. SR-025 head travel 193..640 unchanged. | Run 27 design | 2026-11-02 |
| SR-039 | E-plate service (run 27, supersedes SR-019 and SR-026 door wording): the outer panel L2 (14x M5) must be removed before the inner plate swings 0-90 deg (detent at 90, stop at 95). The panel carries no electrics. The e-plate interlock (SR-009) still applies to the inner plate. Before the panel is removed the touchscreen procedure says: power off, UNPLUG the IEC mains, dump valve vented (pressure switch reads 0), and drain bottle cap closed. With the plate open > 5 deg: no motion, laser locked out, heaters off. A job cannot start until the plate is closed and latched and the pressure switch reads normal again. | Run 27 design | 2026-11-02 |
| SR-040 | Tray L full reach (run 28): tray L is X 147-241 machine (94 x 162), 4x6 cells (pitch 23.0 x 26.7), QR in the front-left cell, 23 usable cells, every cell reached by N1 at head X >= 193 (N1 min X 143, 4 mm margin). SR-035 is revised: neither tray ever blocks a job for reach; the planner still assigns each part to a needle by size. | Run 28 design | 2026-11-02 |
| SR-041 | Pick-and-place cycle (run 28): (1) the tray moves so the target cell is under the needle line (Yc = 105 + 224 - cell Y) and the head puts the chosen needle over the cell X; (2) needle down, vacuum on, pick verified by the vacuum sensor; (3) lift to the retract height, then the tray brings the up-looking OV9281 camera (ring light on) under the needle and the part is inspected from below (presence, polarity mark, X/Y offset, angle); a failed inspection returns the part to its cell and flags it; (4) if the angle error is > 2 deg or the part must turn, it is set on the rotation plate, vacuum off, needle up, and the tray runs into the index zone (SR-014/015 rules apply, head parked) to turn it; the tray returns and the needle re-picks; (5) place on the PCB at the corrected X/Y. The laser stays disarmed for the whole cycle (SR-003). | Run 28 design | 2026-11-02 |
| SR-042 | Ghost space reservation (run 28): the free box below the laser source (ghost_space.json, recomputed every run with all swept envelopes) is reserved for future packages. No software or config change may add motion (new soft limits, new park poses, longer needle strokes) that enters it without re-running the ghost step. | Run 28 design | 2026-11-02 |
| SR-043 | Air interlock (run 29, revised from the r2 air drawing proposal): one BTC-IIS pump feeds both the vacuum and pressure sides, so N7 blow (hot air OR air clean) never overlaps a high-flow PnP vacuum demand. A pick acquisition (N1/N6 needle down, vacuum valve open until the vacuum sensor confirms the seal, max 400 ms) never starts while V5 (N7) is open, and V5 never opens during an acquisition; the planner serializes them. Holding an already sealed part (low flow, from the 225 mL VAC tank) during N7 blow is allowed. While the make-up valve V-MU is open (pressure demand only) no acquisition starts: V-MU closes first and the VAC tank must read <= -50 kPa. VAC tank > -40 kPa during a hold = pause "Vacuum lost". There is no V2 / air-clean vacuum any more. | Run 29, air drawing r3 | 2026-11-02 |
| SR-044 | No debris vacuum, anywhere (run 29): vacuum is used only for N1/N6 component picks. A job step or config that asks for vacuum on any other needle, or for cleaning/debris extraction by vacuum, is rejected at import ("Vacuum is for N1/N6 picks only"). Debris is cleared by N7 air clean (SR-045) into the fume extraction during the laser hood cycle. Revised run 30: vacuum needles are N1/N6 (SR-048). | the designer, run 29; rev. run 30 | 2026-11-02 |
| SR-045 | N7 dual mode (run 29): N7 is both hot air (SR-037) and air clean, same needle and line. Air clean = heater OFF (or a <= 60 C setpoint when the job asks for warm clean); it starts only with the N7 heater-block NTC < 60 C (else wait, max 60 s, then pause "N7 still hot for clean"). Flow 1.2-1.8 L/min, same 1.5 mm standoff rules; SR-043 applies to both modes. The screen shows the mode (HOT AIR / AIR CLEAN) whenever V5 is open. | Run 29 design | 2026-11-02 |
| SR-046 | Laser electronics on the e-plate (run 29): the laser PSU and the JCZ EZCAD controller ride on the inner e-plate (the laser grey base is gone). Opening the e-plate > 5 deg (SR-039 switch) removes laser enable in hardware (W21 relay on the plate) and the software shows "E-plate open - laser locked out"; the controller may stay powered for diagnostics but no mark job is accepted. The only external connections are the chiller loop, the fume exhaust and AC power (revised run 30: all external connections are on the rear service panel, host USB-C on the front, no foot pedal; see SR-049/SR-050). SR-039 is revised: no dump valve, pressure switch or drain bottle steps any more; instead "pump off, tanks vented (both P-sensors read 0 +/- 5 kPa)". | Run 29 design | 2026-11-02 |
| SR-047 | **SUPERSEDED by SR-048 (run 30).** Vacuum picks by N4/N5 only (run 29): N1-N3 and N6 have no vacuum, so the planner assigns every pick to N4 or N5 by size and checks the reach map: tray R X 458-650 (N4, 84 %) and X 458-670 (N5, 93 %), so tray R cells right of X 670 are unusable; tray L only X 203-241 (N4, 40 %) and X 223-241 (N5, 19 %). SR-038 and SR-040 are revised: tray cells outside these ranges are unusable for picks and are greyed in the tray editor; a job that places parts there is blocked with the cell named. | Run 29 design | 2026-11-02 |
| SR-048 | SUPERSEDED by SR-052 in run 31. Was: vacuum picks by N1 and N6 (run 30, supersedes SR-047): N1 (23 ga) has vacuum + blow-off and serves tray L and the PCB; N6 (22 ga) has vacuum + blow-off and serves tray R and the PCB. Reach: N1 tray L 100 %, N6 tray R 100 %, both PCB 100 %, so every tray cell is usable again (SR-038/SR-040 back to their run 28 meaning; the run 29 grey-out is removed). The planner picks with N1 for tray L cells and N6 for tray R cells; for cells both reach it uses the needle with the shorter head move. N2-N4 are stepper cartridges, N5 is an optional puff (no vacuum). A job that asks for vacuum on N2-N5 is rejected at import ("Vacuum is for N1/N6 picks only"). | the designer, run 30 | 2026-11-02 |
| SR-049 | One rear service panel (run 30): AC inlet (C14 + switch + fuse), coolant IN/OUT (QC3/QC4), 4 in fume exhaust, fume-fan outlet (C13, switched), FW-01 flow switch, Ethernet (host link) and the chiller alarm input (M8) are all on the rear service panel; host USB-C is the only front connection (under the HMI pod). The controller switches the C13 fan outlet ON before the laser can arm, waits for FW-01 flow, and keeps the fan on for a 60 s run-on after the last mark. The chiller alarm input opens = "Chiller fault - laser locked out" (laser enable removed, job paused at the next safe point). Ethernet link loss pauses at the next safe point ("Host link lost"). | the designer, run 30 | 2026-11-02 |
| SR-050 | No foot pedal (run 30): the foot pedal input is removed. START and HOLD exist only on the front HMI pod and on the touchscreen; any job/config step that refers to a pedal is rejected at import ("No foot pedal on this machine"). | the designer, run 30 | 2026-11-02 |
| SR-051 | Air pump (run 31, revised run 33 for a needles-only air system): Parker BTX-Connect B2H-050A24KS-50, 24 V (up to 2.3 A), with its built-in driver (PWM speed input + tach output on the JST PALR-06VF connector); there is no separate BLDC driver. The air system serves only the needles: N4, N5 and N8 vacuum pick with blow-off (3/2 valves V-N4, V-N5, V-N8), N1 puff (2/2 valve V-N1) and N7 hot air / air clean (2/2 valve V-N7); there are no air cylinders and no shop-air inlet. A force-guided relay hard-switches the pump 24 V OFF (e-stop, door, fault). The controller sets PWM from the tank sensors with run 33 targets of -60 kPa vacuum (was -70; keeps the pump inside its -558 mmHg / -74 kPa continuous-duty rating) and 0.6 bar pressure (was 1.0; the needles need at most 0.5 bar). The pressure side keeps the 1.0 bar relief valve as an over-pressure guard; pressure > 0.85 bar for 2 s = pump off and "Air over-pressure". Tanks: VAC 225 mL, PRESS 100 mL. SR-043 serialization applies to N4/N5/N8 acquisitions against V-N7. Tach loss for 1 s with PWM > 0, or the target not reached within 10 s, stops the pump (relay off), closes the valves and shows "Air pump fault" (no picks, no N7 blow, no N1 puff). | the designer, run 31; run 33 | 2026-11-03 |
| SR-052 | 8-station head and vacuum picks (run 31, slot map rewritten run 35): slots left to right (tip X offset from the head reference): S1 N7 hot air + air clean (-72), S2 N1 solder balls (-50), S3 N2 flux (-30), S4 N6 solder paste (-10), S5 N4 PnP nozzle Juki 505 type (+10), S6 N8 soft cup 6-8 mm (+30), S7 N5 0402 pick 25 ga (+50), S8 N3 IPA (+70); 20 mm pitch, 200 mm slide, 170 mm cam stroke. The firmware station table (cam carriage X per station = tip X - 35.15 at head 425) must match this map; a mismatch blocks homing ("Station map does not match the head"). N1/N2/N3/N6 each have their own 10 mm class stepper. Vacuum is on N4/N5/N8 only; a job that asks for vacuum on any other station is rejected at import ("Vacuum is for N4/N5/N8 only"). All tray picks use N4/N5/N8 (100 % reach of the tray and the PCB). Every station carries the common front-loading cartridge; the cartridge ID (pogo pins) must match the station map before any motion, and a missing or wrong cartridge blocks the job ("Cartridge N# missing or wrong"). | the designer, run 31 / run 35 | 2026-11-04 (run 35) |
| SR-053 | Companion boards (run 31): a companion board may be machine-placed by N8 only if it weighs <= 50 g and has a flat, bare PnP target at its centre of mass sized for the N8 cup (>= 10 mm circle, silkscreen outline and label "PnP", no parts or vias inside). N8 reaches the PCB only between X 263 and 390 (about 90 % of the 140 mm board), so the planner checks the target X; boards over 50 g, without a target, or with the target out of N8 reach are hand-placed (the job pauses with "Place companion board by hand"). | the designer, run 31 | 2026-11-03 |
| SR-054 | One part tray (run 31): tray L and tray R are replaced by ONE removable tray on the right (192 x 162 mm, 7 x 6 pockets, 41 usable; the front-left cell holds the QR tag). SR-032/SR-034 apply to this single tray. | the designer, run 31 | 2026-11-03 |
| SR-055 | Cam isolation (run 35, deliberate rule): the single linear cam lobe drops the active needle 30 mm; the neighbours on either side sit 10.7 mm down (their tips stay 19.3 mm above the active tip), stations two or more away stay up (< 0.01 mm). While the cam moves between two adjacent stations both needles are partly down. So: (1) the head moves to a station only at safe Z (no part, PCB or tray under any lowered tip), (2) the cam moves only with the head at safe Z, (3) the process height is set by the active tip only, and the planner keeps the neighbours' tips at least 5 mm above the board, part tops and tray walls. | the designer, run 35 | 2026-11-04 |
| SR-056 | Needle sensor and front maintenance pod (run 35): the sensor sits flush in the carrier at front centre and the pod (IPA dip, purge cup, felt wipe, lift-out drip tray) at its right, both in front of the PCB and under the hood band. Every job starts with a sensor pass of all 8 tips (about 8 s); paste, flux and IPA needles purge into the pod before their first dot and wipe on the felt after a purge. The drip tray level is a maintenance item ("Empty the drip tray" after the configured purge count); nothing is required mid-job. | the designer, run 35 | 2026-11-04 |
| SR-057 | Tray layout (run 35): parts for N8 (heavy / large) go in the tray columns nearest the PCB, then N4, then N5, to shorten the long moves; the tray editor suggests this order but allows any pocket. | the designer, run 35 | 2026-11-04 |
| SR-058 | Volume refactor (run 35): a fully tested OSSO PCB with its interposer stack can be refactored by the OSSO software into a single multi-layer PCB, with new sizing and port (connector) locations, for volume manufacturing by a fab. This refactored multi-layer PCB is the final destination of the OSSO prototyping workflow: it is sized and its ports placed to meet the packaging constraints of the final product. Design intent only; see PCB_RULES.md PR-VR. | the designer, run 35 | 2026-11-04 |
Open: whether motion is allowed in HOLD with the door open, or all motion stops (gull-wing drawing, open question 5).