# OSSO run 11 (2026-10-28): the designer's answers applied
Scripts (in ..): run11_model.py (patches system.py, which is unchanged), top_run11.py (exports + renders), run11_checks.py (checks), anim_run11_qc.py (animation).
The original osso_top.* (run 10) is kept for comparison. Run 11 outputs are in this folder.

## What changed vs run 10
- **No cart.** All cart parts, castors, the 4 panel_lower_* panels, the in-cart laser base and chiller, and the LOWER_* routes are removed. The frame posts (FR/RR, zone posts) were cut to z 0..655 (L655).
- **Bench feet.** There are 4 laser-cut 3 alu foot plates and M10 levelling feet with a Ø40 pad. The REF bench is 1650 x 800 x 40, top 850 above the floor. There is a **50 mm service gap** under the bottom panel (**DECIDED 2026-10-28: keep the 50 mm gap**) (bench top at Z -53) because the bottom-plate devices protrude to -20.
  - The cables in the gap run to the rear: IEC mains W27, USB W41, and air H04 → QC1. The pedal W42 runs to the front, and the interlock W21 runs to the laser base.
- **Laser base BESIDE.** It is a separate REF unit (450x350x200) on the bench at X 860-1310, Y 330-680, with a 58 mm gap to the right-panel grille. The chiller REF sits on the floor under the bench (X 790-1370).
  - **Beam path / fiber:** the source stays inside, and the beam path is unchanged. The source↔base umbilical (DB25 + power + DB9, Ø22) drops in the free column at X 765, Y 258 to Z 120. It then exits through a Ø40 brush grommet in the right panel and enters the base's left face (Y 420, Z 80). The old bottom slot and coolant hole get a 1.5 alu cover plate.
  - **Coolant:** the internal pair runs to QC3 (IN, Y 200) and QC4 (OUT, Y 236) dry-break bulkheads in the right panel (Z 180). Outside, the hoses run back past the bench rear edge (Y 785/805), down to the chiller rear.
- **Pneumatic plate 120x150** (Y 578-698, Z 475-625): side-bowl filter-regulator → 3/2 NC dump valve → pressure switch on a tee → PU6 → **QC2** shut-off → X chain. The heater air valve, rotameter, manifold and spare PU6 are removed.
- **Quick-connects:**
  - QC1: 1/4 industrial plug on H04, under the rear edge.
  - QC2: PU6 shut-off on the head supply.
  - QC3/QC4: coolant dry-break couplers, **OD = COOL_OD = 12 placeholder, TBD**. The coupler body is Ø = COOL_OD + 16, and editing COOL_OD regenerates everything.
- **HMI:** the arm is deleted. The bezel and screen are fixed at 18° (the top tilts back about the bottom-front edge) on 2 FDM PETG wedge brackets to the niche back wall. The RPi5 got its own FDM mount plate on the niche back wall, because the deleted arm bracket used to carry it.

## Checks
- **Clash** (4 corner poses of the 48-pose grid, static pairs at pose 1; run11_interference.json):
  - REAL 9: all of them are the pre-existing door group (front panel / piano hinge / brush ring / open catch). These are the same pairs as in run 10, from the run 9 flip-up door.
  - **No new REAL hits.**
  - intra_prior 6 (unchanged), termination 43, bundle 16.
  - Run 10 baseline: REAL 18. The 7 HMI-arm and 2 bottom-grommet hits are gone.
- **Floating parts** (bbox-contact graph from the floor, 1 mm; run11_floating_plane.json): 1, door_open_catch_spring_clip. This is pre-existing and not touched in run 11 (it sits 190 mm in front of the panel; check in the next door pass).
- **Plane check** (machine envelope): 0. QC1 and the outside cables/hoses pass the back plane by design, so the machine needs ~80 mm behind it for the rear exits.

## Key outputs
- osso_top_run11.step: top-level panels / components / bench_feet / bench_ref / subsystems.
- osso_top_run11.glb: has a front_view camera.
- osso_top_run11.usdz
- osso_run11_{iso,front,side,rear_iso}.png, osso_run11_machine_*.png, osso_run11_right_side_QC_*.png, osso_run11_pneu_plate_left_iso.png, osso_run11_hmi_18deg_*.png, osso_run11_under_gap_bottom_iso.png
- osso_run11_qc_disconnect.mp4 / .usdz (stills anim_qc_*.png)

## Flags
- The hot-air heater has no air after the valve and rotameter were dropped, so it must not be energized (PENDING TODO 110).
- The 50 mm gap raises the machine 30 mm over the item-4 concept (20 mm feet), so the HMI heights in bench_hmi_heights.json are +30.
- The coolant OD is TBD (COOL_OD).
- The REF laser base and chiller dimensions are placeholders.